S05 — In-Room Terminal Systems (SI)

Original price was: $52.00.Current price is: $26.00.

Book by ASHRAE,

Category:

Description

Very early in the design process, the HVAC design engineer must analyze and ultimately select appropriate systems, as dis-cussed in Chapter 1. Next, production of heating and cooling is selected as decentralized (see Chapter 2) or centralized (see Chapter 3). Finally, distribution of heating and cooling to the end-use space can be done by an all-air system (see Chapter 4), or a variety of all-water or air/water systems and local terminals, as discussed in this chapter.

System Characteristics
System Components and Configurations
Secondary-Water Distribution
Piping Arrangements
Fan-Coil Unit and Unit Ventilator Systems
Variable-Refrigerant-Flow (VRF) Units
Chilled-Beam Systems
Radiant-Panel Heating Systems
Radiant-Floor Heating Systems
Induction Unit Systems
Supplemental Heating Units
Primary-Air Systems
Performance Under Varying Load
Changeover Temperature
Two-Pipe Systems with Central Ventilation
Four-Pipe Systems
Automatic Controls and Building Management Systems
Maintenance Management Systems and Building System Commissioning

ISBN: 978-1-947192-53-9 (for SI versions of chapters)
ISSN: 1930-7705 (for SI versions of chapters)

Citation: 2020 ASHRAE Handbook¿¿¿HVAC Systems and Equipment

Product Details

ISBN(s):
9781947192539
Number of Pages:
16
Units of Measure:
SI
File Size:
1 file , 630 KB
Product Code(s):
D-S052020SI
Sale!

S05 — In-Room Terminal Systems (SI)

Original price was: $49.00.Current price is: $24.50.

Handbook / Manual / Guide by ASHRAE, 2016

Category:

Description

Very early in the design process, the HVAC design engineer must analyze and ultimately select appropriate systems, as dis-cussed in Chapter 1. Next, production of heating and cooling is selected as decentralized (see Chapter 2) or centralized (see Chapter 3). Finally, distribution of heating and cooling to the end-use space can be done by an all-air system (see Chapter 4), or a variety of all-water or air/water systems and local terminals, as discussed in this chapter.

System Characteristics
System Components and Configurations
Secondary-Water Distribution
Piping Arrangements
Fan-Coil Unit and Unit Ventilator Systems
Variable-Refrigerant-Flow (VRF) Units
Chilled-Beam Systems
Radiant-Panel Heating Systems
Radiant-Floor Heating Systems
Induction Unit Systems
Supplemental Heating Units
Primary-Air Systems
Performance Under Varying Load
Changeover Temperature
Two-Pipe Systems with Central Ventilation
Four-Pipe Systems
Automatic Controls and Building Management Systems
Maintenance Management Systems and Building System Commissioning

ISBN: 978-1-939200-27-3 (for SI versions of chapters)
ISSN: 1930-7705 (for SI versions of chapters)

Citation: 2016 ASHRAE Handbook

Product Details

Published:
2016
ISBN(s):
9781939200273
Number of Pages:
16
Units of Measure:
SI
File Size:
1 file , 820 KB
Product Code(s):
D-S052016SI