Sale!

S18 — Variable Refrigerant Flow (I-P)

Original price was: $52.00.Current price is: $26.00.

Book by ASHRAE,

Category:

Description

Variable-refrigerant-flow (VRF) HVAC systems are a direct-expansion (DX) heat pump technology platform built on the standard reverse Rankine vapor compression cycle. These systems are thermodynamically similar to unitary and other com-mon DX systems, and share many of the same components (i.e., compressor, expansion device, heat exchangers). VRF systems transport heat between an outdoor condensing unit and a network of indoor units located near or within the conditioned space through refrigerant piping installed in the building. Attributes that distinguish VRF from other DX system types are multiple indoor units connected to a common outdoor unit (single or combined modules), scalability, variable capacity, distributed control, and simultaneous heating and cooling.

Standards
Equipment
VRF System Operation
Modeling Considerations
Design Considerations
VRF System Design Example
Commissioning

ISBN: 978-1-947192-52-2 (for I-P versions of chapters)
ISSN: 1078-6066 (for I-P versions of chapters)

Citation: 2020 ASHRAE Handbook — HVAC Systems and Equipment

Product Details

ISBN(s):
9781947192522
Number of Pages:
15
Units of Measure:
I-P
File Size:
1 file , 430 KB
Product Code(s):
D-S182020IP
Sale!

S18 — Variable Refrigerant Flow (I-P)

Original price was: $49.00.Current price is: $24.50.

Handbook / Manual / Guide by ASHRAE, 2016

Category:

Description

Variable-refrigerant-flow (VRF) HVAC systems are a direct-expansion (DX) heat pump technology platform built on the standard reverse Rankine vapor compression cycle. These systems are thermodynamically similar to unitary and other com-mon DX systems, and share many of the same components (i.e., compressor, expansion device, heat exchangers). VRF systems transport heat between an outdoor condensing unit and a network of indoor units located near or within the conditioned space through refrigerant piping installed in the building. Attributes that distinguish VRF from other DX system types are multiple indoor units connected to a common outdoor unit (single or combined modules), scalability, variable capacity, distributed control, and simultaneous heating and cooling.

Standards
Equipment
VRF System Operation
Modeling Considerations
Design Considerations
VRF System Design Example
Commissioning

ISBN: 978-1-939200-26-6 (for I-P versions of chapters)
ISSN: 1078-6066 (for I-P versions of chapters)

Citation: 2016 ASHRAE Handbook — HVAC Systems and Equipment: Chapter 18, Variable-Refrigerant-Flow Systems

Product Details

Published:
2016
ISBN(s):
9781939200266
Number of Pages:
15
Units of Measure:
I-P
File Size:
1 file , 1.7 MB
Product Code(s):
D-S182016IP