Sale!

HI-85-11-2 — Effect of Insulation Joints on Heat Loss through Flat Roofs

Original price was: $15.00.Current price is: $7.50.

Conference Proceeding by ASHRAE, 1985

Category:

Description

Increased heat loss has been measured for several insulation joint arrangements in extruded ad polystyrene placed on a 9-mm thick plywood deck. Butt joints ranging up to 25.4 mm wide, a 3-mm butt joint bevelled to 28 mm at the deck, and a 3-mm shiplap joint were used. Most. of the work was carried out with protected-membrane roof arrangements, but measurements were also made on a conventional roof arrangement with 2.5- and 12.7-mm butt joints.

Sets of two and six heat flux transducers were placed at. the underside of the deck at various locations with respect to the insulation joints . The measured heat fluxes were used to estimate heat flux as a function of distance from the joint and from this to compare heat losses with and without joints.

Units: SI

 

Citation: Symposium, ASHRAE Transactions, 1985, vol. 91, pt. 2B, Honolulu, HI

Product Details

Published:
1985
Number of Pages:
15
File Size:
1 file , 880 KB
Product Code(s):
D-HI-85-11-2