Sale!

HI-85-37-3 — Building Parameters and Their Estimation from Performance Monitoring

Original price was: $15.00.Current price is: $7.50.

Conference Proceeding by ASHRAE, 1985

Category:

Description

This paper defines parameters that characterize the statics and dynamics of a building. A static parameter is the familiar building loss coefficient that we can calculate using element-by-element addition or determine from building performance data by regression. The dynamic parameters are obtained from a natural generalization of the static parameters . These parameters thus share the same characteristics. In this paper we define eight parameters for a one-zone building and give the results from actual performance data, pointing out. extensions and applications. This method is referred to as BEVA (Building Element Vector Analysis).

Units: Dual

 

Citation: Symposium, ASHRAE Transactions, 1985, vol. 91, pt. 2B, Honolulu, HI

Product Details

Published:
1985
Number of Pages:
8
File Size:
1 file , 490 KB
Product Code(s):
D-HI-85-37-3